5 SERVICE FACTOR AMPS PRIMARY 3 Technical Data
4 POLES 4 NUMBER SPEEDS 1 RPM 1775 RPM 2 1775 HERTZ 60 VOLTS PRIMARY 230/460 VOLTS 460 VOLTS 2 230 FRME 286 SHAFT CODE TPA MOUNTING VERT ASSEMBLY POSITION NA MOTOR TYPE AUS OPPOSITE END BEARING 6210-2Z-J/C3 SHAFT END BEARING 7310 BEP AMBIENT 40 SERVICE FACTOR 1
12 KILOWATTS 15 POLES 4 NUMBER SPEEDS 1 RPM 1475 RPM 2 1475 HERTZ 50 VOLTS PRIMARY 230/400 VOLTS 400 VOLTS 2 230 FRME 160 SHAFT CODE B5 MOUNTING HORZ-FOOTLESS ASSEMBLY POSITION NA MOTOR TYPE ICTEF OPPOSITE END BEARING 6209-2Z-J/C3 SHAFT END BEARING 6309-2Z-J/C3 AMBIENT 40 ROTATION DUAL SERVICE FACTOR 1 STARTCAPMFD N\A SHIPPING WEIGHT 345 BREAKDOWN TORQUE 295 BREAKDOWN TORQUE UOM PERCENT OF FLT LOCKED ROTOR TORQUE 307 LOCKED ROTOR TORQUE UOM PERCENT OF FLT INSULATION CLASS F KVA CODE LETTER H LOCKED ROTOR AMPS 199
375 MOTOR TYPE DF OPPOSITE END BEARING BALL SHAFT END BEARING BALL AMBIENT 40 ROTATION CCW DRIVE END SERVICE FACTOR 1
65 SHIPPING WEIGHT 23 THERMAL PROTECTION AUTOMATIC RESET BREAKDOWN TORQUE 18
WEG 01036ST3QIE215TC-W22 W22 IEEE 841 NEMA Premium Efficiency 10 HP 2P 213/5TC 3Ph 460 V 60 Hz IC411 - TEFC - Foot-mounted W22 5 SERVICE FACTOR AMPS PRIMARYThe W22 IEEE 841 motors were especially designed to operate in petrochemical and chemical industries. The motor has cast iron frame, flexible mounting, solid and whole feet, low noise levels, anticorrosive internal coating and high efficiency. Standard NEMA MG 1 Frequency 60 Hz Voltage 460 V Number of poles 2 Degree of Protection IP55 Synchronous speed 3600 rpm Output rating 10 HP Mounting F 1 Flange C Terminal box Left position Enclosure IC411 TEFC